Smart Cleaner
Patent PCT/IL2004/001/151
The Smart Cleaner® is a patented tool for clearing blockages in dental turbines and quick couplings using a helical injector piston movement.
Related products
Patent PCT/IL2004/001/151
The Smart Cleaner® is a patented tool for clearing blockages in dental turbines and quick couplings using a helical injector piston movement.
The Smart Cleaner® serves two purposes:- Removal of blockages caused by micro particles carried in the water supply and inert biofilm residue left in the turbine.
- Prevention of initial residue/particle build ups by using the smart cleaner with hot water at two days intervals.
Blockage Removal In The Turbine
(a) Fit the connector of the Smart Cleaner® to the turbine/quick coupling.(b) Undo Smart Cleaner® threaded handle.
(c) Remove Smart Cleaner® piston.
(d) Half-fill Smart Cleaner® with hot water.
(e) Return piston to Smart Cleaner®, push it inside with normal hand pressure.
(f) If not successful or resistance is too great for normal hand pressure, fit the threaded handle and screw it down to stop.

| Cat. No. | Description | |
|---|---|---|
| Smart Cleaner 5® | Smart Cleaner that fits to Midwest Standard Turbines | ![]() |
| Smart Cleaner 2® | Smart Cleaner that fits to Borden Standard Turbines | ![]() |
| Smart Cupper 1® | A tool for multi hole turbine to be used when only one hole is blocked | ![]() |
| Smart Connect® | Adaptor for contra angle handpiece (E type) | ![]() |
| Smart Tube® | Adaptor for dental unit tube | ![]() |
General Instructions For Smart Cupper®
Smart Cupper® is necessary when, in a multi hole turbine, only one hole is blocked.- Take the bore cup off the case and connect it to the turbine.
- Adjust the hole of the bore cup exactly above the blocked hole in the turbine.
- Connect the turbine with the case clump and close the screw.
- Connect the turbine to the Smart Cleaner® and run a routine cleaning.
General Instructions For Smart Connect®
Smart Connect® is necessary for contra angle handpieces (E Type).- Connect the Smart Cleaner® to the Smart Connect®
- Connect the contra angle handpiece to the Smart Connect®
- Run a routine use - as shown in Smart Cleaner® instructions
General Instructions For Smart Tube®
Smart Tube® is necessary when the turbine tube in the dental unit is blocked.- Disconnect the tube from the dental unit.
- Connect the pin side of the Smart Tube® to the dental unit tube.
- Connect the other side of the Smart Tube® to the Smart Cleaner®
- Run a routine use - as shown in Smart Cleaner® instructions